CellarPro 1800XT Cooling Unit #1086 (for cellars up to 250cuft)

CellarPro 1800XT Cooling Unit #1086 (for cellars up to 250cuft)

$1,850.00

Description

CellarPro 1800XT-ECX Cooling Unit (P/N 1086). NOW WITH COATED ALUMINUM EVAPORATOR COILS FOR LONGER LIFE!  CellarPro engineered the 1800XT-ECX cooling unit for spaces that need extra BTUH and cooling capacity because of warm environments and/or the demands of a commercial establishment. 1800XT-ECX units are more powerful than CellarPro 1800QTL and 1800QT units, but also somewhat louder.

All air-cooled refrigeration equipment requires fresh air intake to dissipate the heat generated by the cooling unit. The fresh air intake CANNOT come from the wine cellar space – it must come from space outside the cellar. Designed for indoor use only, 1800XT-ECX units can operate in environments ranging from 95F to 40F out of the box. To operate the unit in colder temperatures, please see modifications listed on the Features tab.

 

 

 

 

1456 SENSIBLE BTUH @ 55F.
CellarPro 1800XT-ECX cooling units (1/5 Ton Nominal) are suitable for small wine cellars (up to 250 cubic feet), commercial applications and wine cabinets located in garages (in temperatures ranging from 50-95F).

Performance testing shows that this compact unit maintains optimal cellar temperature and humidity conditions more effectively than similar units from competing brands. 1800XT-ECX units use energy-efficient EC fans and are significantly quieter than comparable units from other brands. Visit our Learning Center for data tables, performance charts and product comparisons among different brands.

CellarPro 1800XT-ECX units are sized to replace Breezaire 2200 and Wine-Mate 2500 cooling units. Please confirm equivalent dimensions and airflow prior to purchase.

Our cooling units are designed to be used in properly-constructed wine cellars that are adequately insulated, airtight and sealed with a vapor barrier. In improperly-constructed cellars, the cooling unit will create excess condensation, leading to damage and premature failure of your cooling unit (not covered by warranty).

CONFIGURATIONS:

  • This unit offers a choice of top or rear hot exhaust.
  • The 1800XT requires fresh air intake at the rear of the cooling unit. If sufficient space does not exist to provide sufficient airflow to the rear of the cooling unit, you may need a rear duct kit.
  • 1800 Series cooling units can be installed completely inside the wine cellar when used with our rear duct kit, which allows you to duct the supply and return airflows from the rear of the cooling unit up to 100 equivalent feet (50 feet per duct).
  • Please note:1800 Series cooling units cannot be ducted without auxiliary fan support, which is included with our our rear duct kit.
  • You must located this unit within the cellar, with the following exception: these units can be installed directly above the wine cellar when used with our front intake hood.
  • For installation in environments below 40°F, our compressor heater modification is required.
  • For installation in environments below 20°F down to -20°F, we recommend our Fan-Cycling Switch (P/N 6972) combined with our compressor heater.
  • A CellarPro cooling unit must always be used in the upright position, and should never be operated on its side or upside down.

  • Now with coated aluminum evaporator coils, which are not subject to formicary corrosion, the leading cause of cooling unit failure
  • Energy-efficient EC Fans on both the cold and hot sides, save $26.02 in annual energy costs vs AC fans (assumes 75% runtime and $0.15/kWh)
  • This unit offers a choice of top or rear hot exhaust. If the unit’s location does not provide sufficient room for airflow, you may need to purchase a rear duct kit.
  • Adjustable humidity control combines a high-output compressor with flexible fan cycles to maintain a recommended level of moisture inside your cellar.
  • Extra-large coils generate maximum cooling power.
  • Intuitive LED display panel mounted on the evaporator with digital programmable thermostat is simple and easy to use. Remote thermostat is available as an upgrade.
  • Energy-saver mode, quick-chill mode, and auto-defrost cycle provide convenient solutions to common cellar needs.
  • Temperature set point range is 47F to 62F when the cooling unit is properly sized.
  • Unit operates with minimal vibrations and less noise than comparable units from competitors.
  • Audible and visual alarms and maintenance-needed indicator protect the cooling unit and the wine cellar.
  • 8-foot power cord exits from the rear and plugs into standard 110V receptacles.
  • Common dedicated 15-amp circuit is required to power the unit.
  • 3-amp electric receptacle is provided to run a small lamp.
  • Removable steel case provides access to the internal components for servicing and repair.
  • CellarPro’s 5-Year Standard Warranty, the most thorough in the industry, protects the unit against manufacturing defects.
  • An optional Enhanced Warranty (#1835) is available for additional protection.
  • ETL Tested and Certified to rigorous UL Standards for safety.

OPTIONS:

Cold Temperature

  • Compressor Heater #1727: protects the unit when installed in environments that drop down to 20°F.
  • Fan Cycling Switch #6972: supports the unit in temperatures below 20°F and as low as -20°F when combined with our compressor heater.


Duct Hoods


Remote Control & Probe

  • Remote Display #1603: lets you place the digital panel wherever you want, whether inside or outside the cellar. Includes 10 feet of wiring.
  • Bottle Probe #1434: this remote thermostat with a 10-foot cord overrides the thermostat on the face of the cooling unit, and allows it to monitor air or liquid temperatures at various locations inside the cellar.
  • Extension cords available in 25-foot (#1780) and 50-foot (#1781) lengths.


Other Options & Upgrades

  • Condensate Drain Line: strongly recommended for wine cellar installations (but not required for wine cabinets), a drain line allows excess moisture to drain from the bottom (#7431) or rear (#1606) of the cooling unit.
  • Condensate Drain Line plus Heating Element: combined with a drain line, we add a 100W heating element to burn of excess moisture. Available with bottom (#7432) or rear (#1709) drain lines.
  • Power Cord Modification #1098: normally the cord exits from the rear of the cooling unit, which generally is outside the cellar; this modification moves the cord to the front of the cooling unit, so that it can be plugged into an outlet inside the cellar.
  • Mounting Clips #1095: attached to the front of CellarPro 1800 Series cooling units, these clips are designed to be bolted to the ceiling inside the wine cabinet / cellar.

 

CellarPro 1800 Series Enhanced Warranty #1835

CellarPro Bottle Probe #1434

1800 CellarPro Power Cord Modification #1098

CellarPro Mounting Clips 1800 2-Pk #1092-R

Compressor Crankcase Heater #1727

Fan Cycling Switch #6972:

Remote Control and Display #1603:

Condensate Drain Line:

Condensate Drain Line plus Heating Element:

Duct Intake Hood (Cold Side) #1932

Duct Hood (Hot Side) #7409

Duct Kit (Hot Side) #1439:

 

Limited Warranty Policy

Flat rate subsidized Shipping in the Continental USA

Brand: CellarPro

UPC: 077757010866

Size: 18w x 16 1/2d x 10 1/2h (in)

Weight: 60 lbs

Power/Rating:
115V AC / 60 Hz
Compressor Amps:
– Running: 3 Amps
– Startup: 20.1 Amps
– Total Watts: 263
– Requires: Dedicated 15-Amp Circuit
– Recommended: Surge Protector
Decibels: 47 dBA (Rear)

Capacity: 1456 BTUH @ 60F

1800-Rear Ducted Cut Sheet

Owners Manual 1800