2491 BTUH @ 55°F.
CellarPro’s Mini-Split 3000Sh cooling units (1/3 Ton Nominal) are suitable for wine cellars up to 600 cubic feet in both commercial and residential wine cellars. The 600 cubic feet cellar size assumes that the cellar is constructed with insulation of R19 or better in all walls and ceiling (ie no glass or uninsulated concrete), the cooling unit is not ducted, a setpoint of 55°F inside the cellar and ambient temperatures up to 85°F outside the cellar.
Performance testing shows that this unit maintains optimal cellar temperature and humidity conditions in extreme conditions up to 110°F more effectively than similar units from competing brands. 3000Sh units also are significantly quieter than comparable units from other brands. Visit our Learning Center for data tables, performance charts and product comparisons among different brands.
DESCRIPTION:
CellarPro 3000Sh Cooling Unit (P/N 7402). CellarPro engineered the Mini-Split 3000Sh cooling system to provide maximum cooling power and adjustable humidity control for cellars up to 600 cubic feet. Split refrigeration systems separate the evaporator from the condensing unit, allowing the noise and heat from the condensing unit to be located away from interior living areas. Configurable for internal or external installations, the Mini-Split 3000Sh includes a variable-speed fan on the evaporator with a low setting for quieter operation and a high setting for maximum power. This unit is the same as the 3000S Mini-Split, except that the evaporator is horizontal instead of vertical.
- This unit is designed to separate the heat and noise from the condensing unit from interior living spaces, and can be configured to operate indoors or outdoors in extreme temperature conditions ranging from -20 to 110°F.
- Our Evaporators are built with high-output centrifugal fans which include variable speed settings for your choice of maximum cooling power at the high fan speed, or quieter operation (53.7 decibels) at the low fan speed.
- Adjustable humidity control combines a high-output compressor with flexible fan cycles to maintain a recommended level of moisture inside your cellar.
- Extra-large coils generate maximum cooling power inside the cellar.
- Excess condensate is managed through a 1/2″ drain line that exits from a choice of knockouts in the evaporator.
- Commercial-grade Electrofin coating protects the evaporator coils from leaks and corrosion.
- Intuitive LED display panel with digital programmable thermostat is simple and easy to use.
- Energy-saver mode, quick-chill mode, and auto-defrost cycle provide convenient solutions to common cellar needs.
- Unit operates with minimal vibrations and less noise than comparable units from competitors.
- Audible and visual alarms and maintenance-needed indicator protect the cooling unit and the wine cellar.
- Common dedicated 15-amp circuit is required to power the unit.
- Adjustable mounting brackets are included as standard equipment, and multiple knockouts and access points ensure easy installation.
- Factory-installed Expansion Valve and Liquid Line Solenoid Valve (optional) ensure maximum operating precision and range.
- Removable steel case and refrigerant access valve provides access to the internal components for servicing and repair.
- Sight Glass and Liquid Line Filter/Drier are included for easy installation and maintenance.
- Oversized Receiver allows for long line sets up to 100 equivalent feet and up to 30 vertical feet.
- Auto-reset high-pressure switch protects the system by interrupting power to the compressor when system pressure is too high.
- Evaporator and Condensing Unit are factory-pressurized and shipped with dry nitrogen to ensure leak-free installation.
- CellarPro’s 2-Year/5-Year Warranty, the most thorough in the industry, protects the unit against manufacturing defects.
- An optional Extended Warranty (P/N 7528) is available for additional protection.
- ETL Tested and Certified to rigorous UL Standards for safety.
CONFIGURATIONS:
- CellarPro Mini-Split 3000Sh units are designed to be installed with the evaporator inside the cellar, and the condensing unit in a remote location.
- Our Split refrigeration systems offer a choice of wiring:
- The Condensing unit can be electronically controlled by and wired to the Evaporator (single power source on the Evaporator side). This configuration allows the Condensing unit to be used in temperatures down to 20F with the addition of our compressor heater, or down to -20F with the addition of our fan cycling switchAND compressor heater. This configuration requires a 15-amp dedicated circuit breaker for 3000S and 4000S systems, and a 25-amp dedicated circuit breaker for 6000S and 8000S systems.
- The Condensing unit can be controlled by a Solenoid valve (dual power source, one each to the Evaporator and Condensing units.) This configuration allows the Condensing unit to be used in temperatures down to 20F with the addition of our compressor heater, or 0F with the addition of our fan cycling switchAND compressor heater. This configuration requires the evaporator to be wired to a 15-amp circuit breaker, and the condensing unit to be wired to a dedicated 15-amp circuit breaker for 3000S and 4000S systems, a dedicated 20-amp circuit breaker for 6000S systems, and a dedicated 25-amp circuit breaker for 8000S systems
- Unlike 3000S evaporators, 3000Sh evaporators cannot be ducted from a remote locationand must be located inside the cellar.
- When the control panel is difficult to access, we offer a remote control display kit which is wired to the cooling unit and allows the digital display to be mounted inside or outside the cellar.
- The condensing unit requires 12 inches of unobstructed space in front of the coils, and requires approx. 600-700 CFM of ventilation when installed in a confined space.
- For outdoor installations, we offer an outdoor hood to protect the condensing unit from weather. All outdoor hoods include a compressor heater.
- The evaporator should never be exposed to temperatures below 32F.
- Access to the left and right side of the evaporator unit is required for installation.
- All split systems must be installed and charged on site by a qualified HVAC professional. Line-set equivalent feet must be calculated in accordance with ASHRAE guidelines; refer to our Line Sizing Chart for more information.
- A CellarPro cooling unit must always be used in the upright position, and should never be operated on its side or upside down.
- We ship these units strapped to a pallet via common carrier with curbside delivery. Inside delivery is available for an additional charge.
- To activate your warranty, you must complete and return our Installation Checklist.
OPTIONS:
Cold Temperature
- Compressor Crankcase Heater #1727: protects the unit when installed in environments that drop down to 20°F.
- Fan Cycling Switch #6972: supports the unit in temperatures below 20°F and as low as -20°F when combined with our compressor heater.
Hoods
Outdoor Hood for Mini Split#1766: allows you to install the condensing unit outdoors; all outdoor hoods include a Compressor Heater #1727.
Remote Control & Probe
- Remote Control and Display #1603: lets you place the digital panel wherever you want, whether inside or outside the cellar. Includes 10 feet of wiring.
- Bottle Probe #1434: this remote thermostat with a 10-foot cord overrides the thermostat on the face of the evaporator, and allows it to monitor air or liquid temperatures at various locations inside the cellar.
- Extension cords available in 25-foot (#1780)and 50-foot (#1781)
CellarPro VS Series Enhanced Warranty #1836
Compressor Crankcase Heater #1727
Remote Control and Display #1603:
Duct Intake Hood (Cold Side) Low RH #7408
Duct Intake Hood (Cold Side) High RH #7427
Duct Intake Kit (Cold Side) Low RH#1476
Duct Intake Kit (Cold Side) High RH#7426
Outdoor Hood for Mini Split #1766
Specs:
- Capacity:2491 BTUH @ 55F
- Sizing:
- Size:30 2/5w x 14 2/5d x 13 1/5h (in)
- Weight:105 lb
- Power/Rating:115V AC / 60 Hz
Condensing Unit Dimensions:
– 42 lbs
– 13.5w x 18.9d x 9.1h
Evaporator Unit Dimensions (including brackets):
– 63 lbs
– 30.4w x 14.4d x 13.2h
System Amps:
– Common dedicated 15-amp circuit is required to power the unit.
– Startup: 28.2 Amps
– Unit Amp Rating: 7.4 Amps (high fan speed)
– Total Watts: 526 (med fan speed)
BTUH @ 55F / Evaporator Decibels
– Low Fan Speed: 2144 / 51 dbA
– Med Fan Speed: 2398 / 55 dbA
– High Fan Speed: 2491 / 63 dbA
– 1/3 Ton Nominal
Condensing Unit Decibels
– Indoor: 64
– Outdoor: 62 - Warranty:2 Years (Entire System) To activate your warranty, you must complete and return our Split Installation Checklist.
Optional Extended Warranty sold separately. - SKU:3000Sh
- UPC:682318846527
Front Ducted Evaporator Cut Sheet, Wiring Diagram – Dual Power Valve Control, Condensing Unit Hood, Refrigerant Piping Diagram, Evaporator Cut Sheet, Mounting Instructions, Split Systems Refrigerant Piping Handbook, Owners Manual Split Systems
Only logged in customers who have purchased this product may leave a review.
Related Products
CellarPro Mini-Split 3000Sqc Quickconnect 25-ft #18372 (for cellars up to 600cuft)
2491 BTUH @ 55°F. CellarPro’s Mini-Split 3000Sqh cooling units (1/3 Ton Nominal) are suitable forwine cellars up to 600 cubic feetin bothcommercial and residentialwine cellars. The 600 cubic feet cellar size assumes that the cellar is constructed with insulation of R19 or better in all walls and ceiling (ie no glass or uninsulated concrete), the cooling unit is not ducted, a setpoint of 55°F inside the cellar and ambient temperatures up to 85°F outside the cellar. Our Quickconnect pre-charged hoses and plug-in power cords allow fast, easy installation by technicians or the end customer. The only tool required is an adjustable wrench. Performance testing shows that this unit maintainsoptimal cellar temperature and humidity conditionsin extreme conditions up to 110°F more effectively than similar units from competing brands. 3000Sqc units also aresignificantly quieterthan comparable units from other brands. Visit our Learning Center for data tables, performance charts and product comparisons among different brands. DESCRIPTION: CellarPro 3000Sqc Quickconnect 25-ft Cooling Unit (P/N 18372). CellarPro engineered the Mini-Split 3000Sqc cooling system to provide maximum cooling power and adjustable humidity controlwith fast, easy installationfor cellars up to 600 cubic feet. Split refrigeration systems separate the evaporator from the condensing unit, allowing the noise and heat from the condensing unit to be located away from interior living areas. Suitable for internal or external installations, the Mini-Split 3000Sqc includes a variable-speed fan on the evaporator with a low setting for quieter operation and a high setting for maximum power. This unit is designed to separate the heat and noise from the condensing unit from interior living spaces, and can be configured to operate indoors or outdoors inextreme temperature conditions ranging from -0 to 110F. This model comesfully-charged with 25-ft Quickconnect hoses, so that it can be installed by the end customer without assistance from a refrigeration technician Evaporator, Condensing Unit and Flexible Quickconnect Hoses are factory-charged and shipped with R134a refrigerant. Included outdoor hoodallows the condensing unit to be installed indoors or outdoors Included compressor heaterallows the condensing unit to function in temperatures down to 20F. Optional fan cycling switch (sold separately) allows the condensing unit to operate in temperatures down to 0F Our Evaporators are built withhigh-output centrifugal fanswhich include variable speed settings for your choice of maximum cooling power at the high fan speed, or quieter operation (53.7 decibels) at the low fan speed. Adjustable humidity controlcombines a high-output compressor with flexible fan cycles to maintain a recommended level of moisture inside your cellar. Extra-large coils generatemaximum cooling powerinside the cellar. Excess condensate is managed through a 1/2″ drain line that exits from a choice of knockouts in the evaporator. Commercial-gradeElectrofin coatingprotects the evaporator coils from leaks and corrosion. IntuitiveLED display panelwithdigital programmable thermostatis simple and easy to use. Energy-saver mode, quick-chill mode, and auto-defrost cycle provide convenient solutions to common cellar needs. Unit operates withminimal vibrationsandless noisethan comparable units from competitors. Audible and visual alarms and maintenance-needed indicator protect the cooling unit and the wine cellar. Both the condensing unit and evaporator are configured withplug-in power cords, meaning that an electrician is not required for installation. Adedicated 15-amp circuitis required to power the condensing unit, and the evaporator can be plugged into a shared circuit. Adjustable mounting brackets are included as standard equipment Valves can exit from the side or rear of the evaporator. Rear connections require a 6″ x 2 1/4″ hole in the wall for hoses, power and drain lines. Factory-installed Expansion Valve and Liquid Line Solenoid Valve ensure maximum operating precision and range. Removable steel caseprovides access to the internal components for servicing and repair. Liquid Line Filter/Drier is factory installed. Oversized Receiver allows for long line sets up to 50 equivalent feet and up to 30 vertical feet. Auto-reset high-pressure switch protects the system by interrupting power to the compressor when system pressure is too high. CellarPro’s 2-Year/5-Year Warranty,the most thorough in the industry, protects the unit against manufacturing defects. ETLTested and Certifiedto rigorous UL Standards for safety. CONFIGURATIONS: Quickconnect split units are designed to be installed with the evaporator inside the cellar (or located remotely outside the cellar – see below), and the condensing unit in a remote location. The Condensing unit is controlled by a Solenoid valve (dual power source, one each to the Evaporator and Condensing units.) The Condensing unit comes with an Outdoor Hood and Compressor Heater, and can be used indoors or outdoors in temperatures down to 20F, or0Fwith the addition of ourfan cycling switch(sold separately). This model includes 25-feet of hoseto connect the Evaporator and Condensing Unit. The evaporator can be wired to a shared 15-amp circuit breaker. The condensing unitmustbe wired to adedicated15-amp circuit breaker. The evaporator can belocated remotelyfrom the cellar with the addition of one of our cold-side duct packages. Offered with or without insulated flex ducting, in a choice of configurations for low or high humidity conditions, our front duct packages allow these cooling units to beducted up to 50 equivalent feetaway from the cellar and requires 8-inch (or greater) ducting from start to finish. When calculating equivalent feet,each 90-degree turn counts for 8 feet. When the control panel is difficult to access, we offer a remote control display kit which is wired to the cooling unit and allows the digital display to be mounted inside or outside the cellar. The condensing unit requires 12 inches of unobstructed space in front of the coils, and requires approx. 600-700 CFM of ventilation when installed in a confined space. Our Quickconnect cooling units include an outdoor hood and compressor heater to protect the condensing unit from weather, so the condensing unit can be installed indoors or outdoors in temperatures down to 20F without our fan cycling switch, or 0F with the fan cycling switch (sold separately). The evaporator should never be exposed to temperatures below 32F. The Quickconnect fittings, power cord and drain line can be configured to exit from the rear or left side of the evaporator. When exiting from the rear, the fittings will require an opening in the wall that measures 6″ x 2 1/4″. Unlike most split systems, which must be wired, installed and charged on site by qualified Electrican and HVAC professionals, our Quickconnect systems are pre-charged with refrigerant and use plug-in power cords, so that they can be installed quickly and easily by the end user. A CellarPro cooling unit must always be used in theupright position, and should never be operated on its side or upside down. We ship these units strapped to a pallet via common carrier with curbside delivery. Inside delivery is available for an additional charge. . OPTIONS: Cold Temperature Fan Cycling Switch #6972:supports the unit in temperatures below 20F and as low as -20F when combined with our compressor heater. Duct Hoods Duct Hoods (Cold Side)(#7408for low-humidity environments or#7427for high-humidity environments)and Kits(#1476for low-humidity environments or#7426 for high-humidity environments): permits the evaporator to be located remotely, up to 50 equivalent feet away from the cellar. Duct Kits are the same as Duct Hoods, and also include 2 x 25-feet of 8-inch insulated (R-6) flex ducting. Remote Control & Probe Remote Control and Display #1603:lets you place the digital panel wherever you want, whether inside or outside the cellar. Includes 10 feet of wiring. Bottle Probe #1434: this remote thermostat with a 10-foot cord overrides the thermostat on the face of the cooling unit, and allows it to monitor air or liquid temperatures at various locations inside the cellar. Bottle Probe extension cords are available in 25-foot(#1780)and 50-foot(#1781) CellarPro VS Series Enhanced Warranty #1836 CellarPro Bottle Probe #1434 Compressor Crankcase Heater #1727 Fan Cycling Switch #6972: Remote Control and Display #1603: Duct Intake Hood (Cold Side) Low RH #7408 Duct Intake Hood (Cold Side) High RH #7427 Duct Intake Kit (Cold Side) Low RH#1476 Duct Intake Kit (Cold Side) High RH#7426 Duct Hood (Hot Side) #7407 Duct Kit (Hot Side) #1113: Outdoor Hood for Mini Split #1766 Line Set #1804: Heat Exchanger #1800: Specs: Capacity:2491 BTUH @ 55F Sizing: Size:16 3/5w x 12 3/5d x 22 1/10h (in) Weight:120lb Power/Rating:115V AC / 60 Hz Condensing Unit Dimensions: – 42 lbs – 13.5w x 18.9d x 9.1h Evaporator Unit Dimensions (including brackets): – 40 lbs – 16.6w x 12.6d x 22.1h System Amps: –Dedicated 15-amp circuitis required to power the condensing unit. – Shared 15-amp circuit can be used to power the evaporator. – Startup: 28.2 Amps – Unit Amp Rating: 7.4 Amps (high fan speed) – Total Watts: 526 (med fan speed) BTUH @ 55F / Evaporator Decibels – Low Fan Speed: 2144 / 51 dbA – Med Fan Speed: 2398 / 55 dbA – High Fan Speed: 2491 / 63 dbA – 1/3 Ton Nominal Condensing Unit Decibels – Indoor: 64 – Outdoor: 62 Warranty:2 Years (Entire System) Optional Extended Warranty(sold separately.) UPC:691054542488 Evaporator Cut Sheet , Wiring Diagram – Dual Power Valve Control, Mounting Instructions, Split Systems Refrigerant Piping Handbook Owners Manual Split Systems, Front Ducted Evaporator Cut Sheet, Condensing Unit Hood, Refrigerant Piping Diagram$4,650.00
CellarPro 4000Sqc Split Quickconnect 50-ft #19209 (for cellars up to 1,000cuft)
3938 BTUH @ 55°F. CellarPro’s 4000Sqc cooling units (1/2 Ton Nominal) are suitable for wine cellars up to 1,000 cubic feet in both commercial and residential wine cellars. The 1,000 cubic feet cellar size assumes that the cellar is constructed with insulation of R19 or better in all walls and ceiling (ie no glass or uninsulated concrete), the cooling unit is not ducted, a setpoint of 55°F inside the cellar and ambient temperatures up to 85°F outside the cellar. Our Quickconnect pre-charged hoses and plug-in power cords allow fast, easy installation by technicians and homeowners alike. The only tool required is an adjustable wrench. Performance testing shows that this unit maintains optimal cellar temperature and humidity conditions in extreme conditions up to 110°F more effectively than similar units from competing brands. 4000Sqc units also are significantly quieter than comparable units from other brands. Visit our Learning Center for data tables, performance charts and product comparisons among different brands. DESCRIPTION: CellarPro 4000Sqc Split Quickconnect 50-ft Cooling Unit (P/N 19209). CellarPro engineered the 4000Sqc cooling system to provide maximum cooling power and adjustable humidity control with fast, easy installation for cellars up to 1,000 cubic feet. Split refrigeration systems separate the evaporator from the condensing unit, allowing the noise and heat from the condensing unit to be located away from interior living areas. Suitable for internal or external installations, the Mini-Split 4000Sqc includes a variable-speed fan on the evaporator with a low setting for quieter operation and a high setting for maximum power. This unit is designed to separate the heat and noise from the condensing unit from interior living spaces, and can be configured to operate indoors or outdoors in extreme temperature conditions ranging from -0 to 110F. This model comes fully-charged with 50-ft Quickconnect hoses, so that it can be installed by the end customer without assistance from a refrigeration technician Evaporator, Condensing Unit and Flexible Quickconnect Hoses are factory-charged and shipped with R134a refrigerant. Included outdoor hood allows the condensing unit to be installed indoors or outdoors Included compressor heater allows the condensing unit to function in temperatures down to 20F. Optional fan cycling switch (sold separately) allows the condensing unit to operate in temperatures down to 0F Our Evaporators are built with high-output centrifugal fans which include variable speed settings for your choice of maximum cooling power at the high fan speed, or quieter operation (53.7 decibels) at the low fan speed. Adjustable humidity control combines a high-output compressor with flexible fan cycles to maintain a recommended level of moisture inside your cellar. Extra-large coils generate maximum cooling power inside the cellar. Excess condensate is managed through a 1/2″ drain line that exits from a choice of knockouts in the evaporator. Commercial-grade Electrofin coating protects the evaporator coils from leaks and corrosion. Intuitive LED display panel with digital programmable thermostat is simple and easy to use. Energy-saver mode, quick-chill mode, and auto-defrost cycle provide convenient solutions to common cellar needs. Unit operates with minimal vibrations and less noise than comparable units from competitors. Audible and visual alarms and maintenance-needed indicator protect the cooling unit and the wine cellar. Both the condensing unit and evaporator are configured with plug-in power cords, meaning that an electrician is not required for installation. A dedicated 15-amp circuit is required to power the condensing unit, and the evaporator can be plugged into a shared circuit. Adjustable mounting brackets are included as standard equipment. Valves can exit from the side or rear of the evaporator. Rear connections require a 6″ x 2 1/4″ hole in the wall for hoses, power and drain lines. Factory-installed Expansion Valve and Liquid Line Solenoid Valve ensure maximum operating precision and range. Removable steel case provides access to the internal components for servicing and repair. Liquid Line Filter/Drier is factory installed. Oversized Receiver allows for long line sets up to 50 equivalent feet and up to 30 vertical feet. Auto-reset high-pressure switch protects the system by interrupting power to the compressor when system pressure is too high. CellarPro’s 2-Year/5-Year Warranty, the most thorough in the industry, protects the unit against manufacturing defects. ETL Tested and Certified to rigorous UL Standards for safety. CONFIGURATIONS: Quickconnect split units are designed to be installed with the evaporator inside the cellar (or located remotely outside the cellar – see below), and the condensing unit in a remote location. This model includes 50-feet of hose to connect the Evaporator and Condensing Unit. The Condensing unit is controlled by a Solenoid valve (dual power source, one each to the Evaporator and Condensing units.) The Condensing unit comes with an Outdoor Hood and Compressor Heater, and can be used indoors or outdoors in temperatures down to 20F, or 0F with the addition of our fan cycling switch(sold separately). The evaporator can be wired to a shared 15-amp circuit breaker. The condensing unit must be wired to a dedicated 15-amp circuit breaker. The evaporator can be located remotelyfrom the cellar with the addition of one of our cold-side duct packages. Offered with or without insulated flex ducting, in a choice of configurations for low or high humidity conditions, our front duct packages allow these cooling units to be ducted up to 50 equivalent feet away from the cellar and requires 8-inch (or greater) ducting from start to finish. When calculating equivalent feet, each 90-degree turn counts for 8 feet. When the control panel is difficult to access, we offer a remote control display kit which is wired to the cooling unit and allows the digital display to be mounted inside or outside the cellar. The condensing unit requires 12 inches of unobstructed space in front of the coils, and requires approx. 600-700 CFM of ventilation when installed in a confined space. Our Quickconnect cooling units include an outdoor hood and compressor heater to protect the condensing unit from weather, so the condensing unit can be installed indoors or outdoors in temperatures down to 20F without our fan cycling switch, or 0F with the fan cycling switch (sold separately). The evaporator should never be exposed to temperatures below 32F. The Quickconnect fittings, power cord and drain line can be configured to exit from the rear or left side of the evaporator. When exiting from the rear, the fittings will require an opening in the wall that measures 6″ x 2 1/4″. Unlike most split systems, which must be wired, installed and charged on site by qualified Electrican and HVAC professionals, our Quickconnect systems are pre-charged with refrigerant and use plug-in power cords, so that they can be installed quickly and easily by the end user. A CellarPro cooling unit must always be used in the upright position, and should never be operated on its side or upside down. We ship these units strapped to a pallet via common carrier with curbside delivery. Inside delivery is available for an additional charge. OPTIONS: Cold Temperature Fan Cycling Switch #6972: supports the unit in temperatures below 20F and as low as -20F when combined with our compressor heater. Duct Hoods Duct Hoods (Cold Side)(#7408 for low-humidity environments or #7427 for high-humidity environments) and Kits (#1476 for low-humidity environments or #7426 for high-humidity environments): permits the evaporator to be located remotely, up to 50 equivalent feet away from the cellar. Duct Kits are the same as Duct Hoods, and also include 2 x 25-feet of 8-inch insulated (R-6) flex ducting. Remote Control & Probe Remote Control and Display #1603: lets you place the digital panel wherever you want, whether inside or outside the cellar. Includes 10 feet of wiring. Bottle Probe #1434: this remote thermostat with a 10-foot cord overrides the thermostat on the face of the cooling unit, and allows it to monitor air or liquid temperatures at various locations inside the cellar. Bottle Probe extension cords are available in 25-foot (#1780)and 50-foot (#1781) CellarPro VS Series Enhanced Warranty #1836 CellarPro Bottle Probe #1434 Compressor Crankcase Heater #1727 Fan Cycling Switch #6972: Remote Control and Display #1603: Duct Intake Hood (Cold Side) Low RH #7408 Duct Intake Hood (Cold Side) High RH #7427 Duct Intake Kit (Cold Side) Low RH#1476 Duct Intake Kit (Cold Side) High RH#7426 Duct Hood (Hot Side) #7407 Duct Kit (Hot Side) #1113: Outdoor Hood #2011 Line Set #1804: Heat Exchanger #1800: Specs: Capacity:3938 BTUH @ 55F Sizing: Size:16 3/5w x 12 3/5d x 22 1/10h (in) Weight:120lb Power/Rating:115V AC / 60 Hz Condensing Unit Dimensions: – 42 lbs – 13.5w x 18.9d x 9.1h Evaporator Unit Dimensions (including brackets): – 40 lbs – 16.6w x 12.6d x 22.1h System Amps: – Dedicated 15-amp circuit is required to power the condensing unit. – Shared 15-amp circuit can be used to power the evaporator. – Startup: 40.0 Amps – Unit Amp Rating: 10.6 Amps (high fan speed) – Total Watts: 713 (med fan speed) BTUH @ 55F / Evaporator Decibels – Low Fan Speed: 3282/ 51 dbA – Med Fan Speed: 3617 / 55 dbA – High Fan Speed: 3938 / 63 dbA – 1/2 Ton Nominal Condensing Unit Decibels – Indoor: 64 – Outdoor: 62 Warranty:2 Years (Entire System) Optional Extended Warranty(sold separately.) UPC:691054542518 Front Ducted Evaporator Cut Sheet, Wiring Diagram – Dual Power Valve Control, Condensing Unit Hood, Refrigerant Piping Diagram, Evaporator Cut Sheet, Mounting Instructions, Split Systems Refrigerant Piping Handbook, Owners Manual Split Systems$5,495.00
CellarPro 4000Sh Horizontal Split System 220V 50/60Hz #16270 (for cellars up to 1,000cuft or 21 cubic meters)
3115 BTUH @ 15°C/50Hz. CellarPro’s 4000S 220V 1/3 Ton Nominal cooling units are suitable forwine cellars up to 21 cubic metersin bothcommercial and residentialwine cellars. The 21 cubic meter cellar size assumes that the cellar is constructed with insulation of R19 or better in all walls and ceiling (ie no glass or uninsulated concrete), the cooling unit is not ducted, a set point of 13°C inside the cellar and ambient temperatures up to 27°C outside the cellar. Performance testing shows that this unit maintainsoptimal cellar temperature and humidity conditionsin extreme conditions up to 43°C more effectively than similar units from competing brands. 4000Sh 220V units also are significantly quieter than comparable units from other brands. This unitmay be used in North Americaas well as overseas markets. Visit our Learning Center for data tables, performance charts and product comparisons among different brands. DESCRIPTION: CellarPro 4000Sh 220V Cooling Unit (P/N 16270). CellarPro engineered the 4000Sh 220V cooling system to provide maximum cooling power and adjustable humidity control for cellars up to 21 cubic meters in 220V environments with 50Hz or 60Hz. Split refrigeration systems separate the evaporator from the condensing unit, allowing the noise and heat from the condensing unit to be located away from interior living areas. Configurable for internal or external installations, the 4000S 220V includes a variable-speed fan on the evaporator with a low setting for quieter operation and a high setting for maximum power. This unit is the same as the 4000S 220V, except that the evaporator is horizontal instead of vertical. This unit is designed to separate the heat and noise from the condensing unit from interior living spaces, and can be configured to operate indoors or outdoors inextreme temperature conditions ranging from -29 to 43°C. Our Evaporators are built with high-output centrifugal fans which include variable speed settings for your choice of maximum cooling power at the high fan speed, or quieter operation (53.7 decibels) at the low fan speed. Adjustable humidity controlcombines a high-output compressor with flexible fan cycles to maintain a recommended level of moisture inside your cellar. Extra-large coils generatemaximum cooling powerinside the cellar. Excess condensate is managed through a 1.3-cm drain line that exits from a choice of knockouts in the evaporator. Commercial-gradeElectrofin coatingprotects the evaporator coils from leaks and corrosion. IntuitiveLED display panelwithdigital programmable thermostatis simple and easy to use. Energy-saver mode, quick-chill mode, and auto-defrost cycle provide convenient solutions to common cellar needs. Unit operates withminimal vibrationsandless noisethan comparable units from competitors. Audible and visual alarms and maintenance-needed indicator protect the cooling unit and the wine cellar. Commondedicated 15-amp circuitis required to power the unit. Adjustable mounting brackets are included as standard equipment, and multiple knockouts and access points ensure easy installation. Factory-installed Expansion Valve and Liquid Line Solenoid Valve (optional) ensure maximum operating precision and range. Removable steel case and refrigerant access valveprovides access to the internal components for servicing and repair. Sight Glass and Liquid Line Filter/Drier are included for easy installation and maintenance. Oversized Receiver allows for long line sets up to 30 equivalent meters and up to 9 vertical meters. Auto-reset high-pressure switch protects the system by interrupting power to the compressor when system pressure is too high. Evaporator and Condensing Unit are factory-pressurized and shipped with dry nitrogen to ensure leak-free installation. CellarPro’s 1-Year Warrantyprotects the unit against manufacturing defects. Warrantyprotects the unit against manufacturing defects. CONFIGURATIONS: CellarPro 4000Sh 220V units are designed to be installed with the evaporator inside the cellar, and the condensing unit in a remote location. Our Split refrigeration systems offer a choice of wiring: The Condensing unit can be electronically controlled by and wired to the Evaporator (single power source on the Evaporator side). This configuration allows the Condensing unit to be used in temperatures down to -6.7°C with the addition of our compressor heater, or down to -29°C with the addition of our fan cycling switchAND compressor heater. This configuration requires a 15-amp dedicated circuit breaker for 4000Sh 220V systems, and a 25-amp dedicated circuit breaker for 6000S 220V systems. The Condensing unit can be controlled by a Solenoid valve (dual power source, one each to the Evaporator and Condensing units.) This configuration allows the Condensing unit to be used in temperatures down to -6.7°C with the addition of our compressor heater, or-18°Cwith the addition of ourfan cycling switchAND compressor heater. This configuration requires the evaporator to be wired to a 15-amp circuit breaker, and the condensing unit to be wired to a dedicated 15-amp circuit breaker for 4000Sh 220V systems, a dedicated 20-amp circuit breaker for 6000S 220V systems. Unlike 4000S 220V evaporators, 4000Sh 220V evaporatorscannot be ducted from a remote locationand must be located inside the cellar. When the control panel is difficult to access, we offer a remote control display kit which is wired to the cooling unit and allows the digital display to be mounted inside or outside the cellar. The condensing unit requires 30 centimeters of unobstructed space in front of the coils, and requires approx. 600-700 CFM of ventilation when installed in a confined space. For outdoor installations, we offer an outdoor hood to protect the condensing unit from weather. All outdoor hoods include a compressor heater. The evaporator should never be exposed to temperatures below 0°C. Access to the left and right side of the evaporator unit is required for installation. All split systems must be installed and charged on site by a qualified HVAC professional. Line-set equivalent feet must be calculated in accordance with ASHRAE guidelines; refer to our Line Sizing Chartfor more information. A CellarPro cooling unit must always be used in theupright position, and should never be operated on its side or upside down. We ship these units strapped to a pallet via common carrier with curbside delivery. Inside delivery is available for an additional charge. To activate your warranty, you must complete and return ourInstallation Checklist. OPTIONS: Cold Temperature Compressor Crankcase Heater #1727:protects the unit when installed in environments that drop down to -6.7°C. Fan Cycling Switch #6972: supports the unit in temperatures below -6.7C°C and as low as -29°C when combined with our compressor heater. Hoods Outdoor Hood #1766: allows you to install the condensing unit outdoors; all outdoor hoods include a Compressor Crankcase Heater #1727. Remote Control & Probe Remote Control and Display #1603: lets you place the digital panel wherever you want, whether inside or outside the cellar. Includes 3 meters of wiring. Bottle Probe #1434: this remote thermostat with a 3-meter cord overrides the thermostat on the face of the evaporator, and allows it to monitor air or liquid temperatures at various locations inside the cellar. Extension cords available in 7.5-meter and 15-meter lengths. CellarPro VS Series Enhanced Warranty #1836 CellarPro Bottle Probe #1434 Compressor Crankcase Heater #1727 Fan Cycling Switch #6972: Remote Control and Display #1603: Duct Intake Hood (Cold Side) Low RH #7408 Duct Intake Hood (Cold Side) High RH #7427 Duct Intake Kit (Cold Side) Low RH#1476 Duct Intake Kit (Cold Side) High RH#7426 Duct Hood (Hot Side) #7407 Duct Kit (Hot Side) #1113: Outdoor Hood for Mini Split #1766 Line Set #1804: Heat Exchanger #1800: Specs: Capacity:3387 BTUH @ 50Hz / 15C Sizing: Size:77 1/5w x 36 3/5d x 33 1/2h (cm) Weight:110lb Power/Rating:220V AC 50/60 Hz Condensing Unit Dimensions: – 20.4 kg – 34.3w x 48d x 23h (cm) Evaporator Unit Dimensions (including mounting brackets): – 18.1 kg – 72.2w x 33.5d x 36.6h (cm) System Amps: – Commondedicated 15-amp circuitis required to power the unit. – Startup: 13.1 Amps – Unit Amp Rating: 5.6 Amps (high fan speed) – Total Watts: 680 (med fan speed) BTUH @ 13C / 60Hz Evaporator Decibels – Low Fan Speed: 2823 / 53 dbA – Med Fan Speed: 3111 / 59 dbA – High Fan Speed: 3387 / 67 dbA BTUH @ 13C / 50Hz Evaporator Decibels – Low Fan Speed: 2396 / 53 dbA – Med Fan Speed: 2640 / 59 dbA – High Fan Speed: 2875 / 67 dbA1/4 Ton NominalCondensing Unit Decibels – Indoor: 64 – Outdoor: 62 Warranty:1 Year (Entire System)To activate your warranty, you must complete and return ourSplit Installation Checklist. SKU:4000Sh-220V UPC:682318846251 Front Ducted Evaporator Cut Sheet, Wiring Diagram – Dual Power Valve Control, Condensing Unit Hood, Refrigerant Piping Diagram, Evaporator Cut Sheet, Mounting Instructions, Split Systems Refrigerant Piping Handbook, Owners Manual Split Systems$4,550.00
CellarPro 6000S Split System 220V 50/60Hz #7345 (for cellars up to 1,500cuft or 35 cubic meters)
4707 BTUH @ 15°C/50Hz. CellarPro’s 6000S 220V 1/2 Ton Nominal cooling units are suitable forwine cellars up to 35 cubic metersin bothcommercial and residentialwine cellars. The 35 cubic meters cellar size assumes that the cellar is constructed with insulation of R19 or better in all walls and ceiling (ie no glass or uninsulated concrete), the cooling unit is not ducted, a setpoint of 13°C inside the cellar and ambient temperatures up to 27°C outside the cellar. Performance testing shows that this unit maintainsoptimal cellar temperature and humidity conditionsin extreme conditions up to 43°C more effectively than similar units from competing brands. 6000S 220V units also are significantly quieter than comparable units from other brands. This unitmay be used in North Americaas well as in overseas markets.Visit our Learning Center for data tables, performance charts and product comparisons among different brands. DESCRIPTION: CellarPro 6000S 220V Cooling Unit (P/N 7345). CellarPro engineered the 6000S 220V cooling system to provide maximum cooling power and adjustable humidity control for cellars up to 35 cubic meters in 220V environments with 50Hz or 60Hz. Split refrigeration systems separate the evaporator from the condensing unit, allowing the noise and heat from the condensing unit to be located away from interior living areas. Configurable for internal or external installations, the 6000S 220V includes a variable-speed fan on the evaporator with a low setting for quieter operation and a high setting for maximum power. This unit is designed to separate the heat and noise from the condensing unit from interior living spaces, and can be configured to operate indoors or outdoors inextreme temperature conditions ranging from -29 to 43°C. Our Evaporators are built with high-output centrifugal fans which include variable speed settings for your choice of maximum cooling power at the high fan speed, or quieter operation (53.7 decibels) at the low fan speed. Adjustable humidity controlcombines a high-output compressor with flexible fan cycles to maintain a recommended level of moisture inside your cellar. Extra-large coils generatemaximum cooling powerinside the cellar. Excess condensate is managed through a 1.3-cm drain line that exits from a choice of knockouts in the evaporator. Commercial-gradeElectrofin coatingprotects the evaporator coils from leaks and corrosion. IntuitiveLED display panelwithdigital programmable thermostatis simple and easy to use. Energy-saver mode, quick-chill mode, and auto-defrost cycle provide convenient solutions to common cellar needs. Unit operates withminimal vibrationsandless noisethan comparable units from competitors. Audible and visual alarms and maintenance-needed indicator protect the cooling unit and the wine cellar. Commondedicated 20-amp circuit (valve control) or 25-amp circuit (electronic control)is required to power the unit. Adjustable mounting brackets are included as standard equipment, and multiple knockouts and access points ensure easy installation. Factory-installed Expansion Valve and Liquid Line Solenoid Valve (optional) ensure maximum operating precision and range. Removable steel case and refrigerant access valveprovides access to the internal components for servicing and repair. Sight Glass and Liquid Line Filter/Drier are included for easy installation and maintenance. Oversized Receiver allows for long line sets up to 30 equivalent meters and up to 9 vertical meters. Auto-reset high-pressure switch protects the system by interrupting power to the compressor when system pressure is too high. Evaporator and Condensing Unit are factory-pressurized and shipped with dry nitrogen to ensure leak-free installation. CellarPro’s 1-Year Warrantyprotects the unit against manufacturing defects. CONFIGURATIONS: CellarPro 6000Sh 220V units are designed to be installed with the evaporator inside the cellar, and the condensing unit in a remote location. Our Split refrigeration systems offer a choice of wiring: The Condensing unit can be electronically controlled by and wired to the Evaporator (single power source on the Evaporator side). This configuration allows the Condensing unit to be used in temperatures down to -6.7°C with the addition of our compressor heater, or down to -29°C with the addition of our fan cycling switchAND compressor heater. This configuration requires a 25-amp dedicated circuit breaker. The Condensing unit can be controlled by a Solenoid valve (dual power source, one each to the Evaporator and Condensing units.) This configuration allows the Condensing unit to be used in temperatures down to -6.7°C with the addition of our compressor heater, or-18°Cwith the addition of ourfan cycling switchAND compressor heater. This configuration requires the evaporator to be wired to a 15-amp circuit breaker, and the condensing unit to be wired to a dedicated 20-amp circuit breaker. 6000Sh 220V evaporatorscannot be ducted from a remote locationand must be located inside the cellar. When the control panel is difficult to access, we offer a remote control display kit which is wired to the cooling unit and allows the digital display to be mounted inside or outside the cellar. The condensing unit requires 30 centimeters of unobstructed space in front of the coils, and requires approx. 600-700 CFM of ventilation when installed in a confined space. For outdoor installations, we offer an outdoor hood to protect the condensing unit from weather. All outdoor hoods include a compressor heater. The evaporator should never be exposed to temperatures below 0°C. Access to the left and right side of the evaporator unit is required for installation. All split systems must be installed and charged on site by a qualified HVAC professional. Line-set equivalent feet must be calculated in accordance with ASHRAE guidelines; refer to our Line Sizing Chartfor more information. A CellarPro cooling unit must always be used in theupright position, and should never be operated on its side or upside down. We ship these units strapped to a pallet via common carrier with curbside delivery. Inside delivery is available for an additional charge. To activate your warranty, you must complete and return ourInstallation Checklist. OPTIONS: Cold Temperature Compressor Heater #1727:protects the unit when installed in environments that drop down to -6.7°C. Fan Cycling Switch #6972: supports the unit in temperatures below -6.7C°C and as low as -29°C when combined with our compressor heater. Hoods Outdoor Hood #2009: allows you to install the condensing unit outdoors; all outdoor hoods include aCompressor Heater #1727. Remote Control & Probe Remote Display #1603: lets you place the digital panel wherever you want, whether inside or outside the cellar. Includes 3 meters of wiring. Bottle Probe #1434: this remote thermostat with a 3-meter cord overrides the thermostat on the face of the evaporator, and allows it to monitor air or liquid temperatures at various locations inside the cellar. Extension cords available in 7.5-meter and 15-meter lengths. CellarPro VS Series Enhanced Warranty #1836 CellarPro Bottle Probe #1434 Compressor Crankcase Heater #1727 Fan Cycling Switch #6972: Remote Control and Display #1603: Duct Intake Hood (Cold Side) Low RH #7408 Duct Intake Hood (Cold Side) High RH #7427 Duct Intake Kit (Cold Side) Low RH#1476 Duct Intake Kit (Cold Side) High RH#7426 Duct Hood (Hot Side) #7407 Duct Kit (Hot Side) #1113: Outdoor Hood #2009 Line Set #1807: Heat Exchanger #16733: Specs: Capacity:4707 BTUH @ 50Hz / 15C Sizing: Size:77 1/5w x 36 3/5d x 33 1/2h (cm) Weight:39kg Power/Rating:220V AC 50/60 Hz Condensing Unit Dimensions: – 20.4 kg – 35.3w x 48d x 30.2h (cm) Evaporator Unit Dimensions (including brackets): – 18.1 kg – 77.2w x 36.6d x 33.5h (cm) System Amps: – Commondedicated 20-amp circuit (valve control) or 25-amp circuit (electronic control)is required to power the unit. – Startup: 18.6 Amps – Unit Amp Rating: 10.8 Amps (high fan speed) – Total Watts: 1196 (med fan speed) BTUH @ 13C / 60Hz / Evaporator Decibels – Low Fan Speed: 4311 / 56 dbA – Med Fan Speed: 4880 / 61 dbA – High Fan Speed: 5046 / 69 dbA BTUH @ 13C / 50Hz / Evaporator Decibels – Low Fan Speed: 3751 / 56 dbA – Med Fan Speed: 4246 / 61 dbA – High Fan Speed: 4390 / 69 dbA- 1/4 Ton Nominal Condensing Unit Decibels – Indoor: 65 – Outdoor: 63 Warranty:1 Year (Entire System)To activate your warranty, you must complete and return ourSplit Installation Checklist. SKU:6000S-220V UPC:682318846503 Owners Manual Split Systems Split Systems Refrigerant Piping Handbook$4,995.00
CellarPro Ceiling Mount Mini-Split 3000Scm #17973 (for cellars up to 600cuft)
2491 BTUH @ 55°F. CellarPro’s Mini-Split 3000Scm split cooling systems with ceiling mounted evaporators (1/3 Ton Nominal) are suitable for wine cellars up to 600 cubic feet in both commercial and residential wine cellars. The 600 cubic feet cellar size assumes that the cellar is constructed with insulation of R19 or better in all walls and ceiling (ie no glass or uninsulated concrete), a setpoint of 55°F inside the cellar and ambient temperatures up to 85°F outside the cellar. Performance testing shows that this unit maintains optimal cellar temperature and humidity conditions in extreme conditions up to 110°F more effectively than similar units from competing brands. 3000Scm units also are significantly quieter than comparable units from other manufacturers. All ceiling-mount units include our remote display with 20-feet of low-voltage wiring (additional wiring available upon request) and an integrated condensate pump as standard equipment. Visit our Learning Center for data tables, performance charts and product comparisons among different brands. DESCRIPTION: CellarPro Ceiling Mount Mini-Split 3000Scm (P/N 17973). CellarPro engineered the Ceiling Mount Mini-Split 3000Scm cooling system to provide maximum cooling power and adjustable humidity control for cellars up to 600 cubic feet, with a ceiling-mounted evaporator enclosed in a stainless-steel case that saves space and therefore maximizes racking capacity on the walls. Split refrigeration systems separate the evaporator from the condensing unit, allowing the noise and heat from the condensing unit to be located away from interior living areas. Configurable for internal or external installations, the Mini-Split 3000Scm includes a variable-speed fan on the evaporator with a low setting for quieter operation and a high setting for maximum power. This unit is designed to separate the heat and noise from the condensing unit from interior living spaces, and can be configured to operate indoors or outdoors in extreme temperature conditions ranging from -20 to 110F. Our Evaporators are built with high-output centrifugal fans which include variable speed settings for your choice of maximum cooling power at the high fan speed, or quieter operation (54 decibels) at the low fan speed. Adjustable humidity control combines a high-output compressor with flexible fan cycles to maintain a recommended level of moisture inside your cellar. Extra-large coils generate maximum cooling power inside the cellar. Excess condensate is managed through an internal integrated condensate pump and a 1/4″ drain line that exits from a choice of knockouts in the evaporator. The pump has automatic overflow protection. Commercial-grade Electrofin coating protects the evaporator coils from leaks and corrosion. Remote LED display panel and digital programmable controls includes 20-feet of wiring and can be mounted inside or outside the cellar. Quick-chill mode, and auto-defrost cycle provide convenient solutions to common cellar needs. Unit operates with minimal vibrations and less noise than comparable units from competitors. Audible and visual alarms and maintenance-needed indicator protect the cooling unit and the wine cellar. Multiple knockouts and access points ensure easy installation. Common dedicated 15-amp circuit is required to power the unit. Factory-installed Expansion Valve and Liquid Line Solenoid Valve (optional) ensure maximum operating precision and range. Removable stainless steel case and refrigerant access valve provides access to the internal components for servicing and repair. Sight Glass and Liquid Line Filter/Drier are included for easy installation and maintenance. Oversized Receiver allows for long line sets up to 100 equivalent feet and up to 30 vertical feet. Auto-reset high-pressure switch protects the system by interrupting power to the compressor when system pressure is too high. Evaporator and Condensing Unit are factory-pressurized and shipped with dry nitrogen to ensure leak-free installation. CellarPro’s 2-Year/5-Year Warranty, the most thorough in the industry, protects the unit against manufacturing defects. An optional Extended Warranty (P/N 7528) is available for additional protection. ETL Tested and Certified to rigorous UL Standards for safety. CONFIGURATIONS: CellarPro Mini-Split 3000Scm units are designed to be installed with the evaporator attached to the ceiling inside the cellar, and the condensing unit in a remote location. Our Split refrigeration systems offer a choice of wiring: The Condensing unit can be electronically controlled by and wired to the Evaporator (single power source on the Evaporator side). This configuration allows the Condensing unit to be used in temperatures down to 20F with the addition of our compressor heater, or down to -20F with the addition of our fan cycling switchAND compressor heater. This configuration requires a 15-amp dedicated circuit breaker for 3000Scm and 4000Scm systems, and a 25-amp dedicated circuit breaker for 6000Scm and 8000Scm systems. The Condensing unit can be controlled by a Solenoid valve (dual power source, one each to the Evaporator and Condensing units.) This configuration allows the Condensing unit to be used in temperatures down to 20F with the addition of our compressor heater, or 0F with the addition of our fan cycling switch AND compressor heater. This configuration requires the evaporator to be wired to a 15-amp circuit breaker, and the condensing unit to be wired to a dedicated 15-amp circuit breaker for 3000Scm and 4000Scm systems, a dedicated 20-amp circuit breaker for 6000Scm systems, and a dedicated 25-amp circuit breaker for 8000Scm systems The condensing unit requires 12 inches of unobstructed space in front of the coils, and requires approx. 600-700 CFM of ventilation when installed in a confined space. For outdoor installations, we offer an outdoor hood to protect the condensing unit from weather. All outdoor hoods include a compressor heater. All split systems must be installed and charged on site by a qualified HVAC professional. Line-set equivalent feet must be calculated in accordance with ASHRAE guidelines; refer to our Line Sizing Chart for more information. A CellarPro cooling unit must always be used in the upright position, and should never be operated on its side or upside down. We ship these units strapped to a pallet via common carrier with curbside delivery. Inside delivery is available for an additional charge. To activate your warranty, you must complete and return our Installation Checklist. OPTIONS: Cold Temperature Compressor Crankcase Heater #1727:protects the unit when installed in environments that drop down to 20F. Fan Cycling Switch #6972: supports the unit in temperatures below 20F and as low as -20F when combined with our compressor heater. Hoods Outdoor Hood for Mini Split #1766: allows you to install the condensing unit outdoors; all outdoor hoods include a Compressor Heater #1727. Bottle Probe #1434: this remote thermostat with a 10-foot cord overrides the thermostat on the face of the evaporator, and allows it to monitor air or liquid temperatures at various locations inside the cellar. Extension cords available in 25-foot(#1780) and 50-foot (#1781) CellarPro VS Series Enhanced Warranty #1836 CellarPro Bottle Probe #1434 Compressor Crankcase Heater #1727 Fan Cycling Switch #6972: Remote Control and Display #1603: Duct Intake Hood (Cold Side) Low RH #7408 Duct Intake Hood (Cold Side) High RH #7427 Duct Intake Kit (Cold Side) Low RH#1476 Duct Intake Kit (Cold Side) High RH#7426 Duct Hood (Hot Side) #7407 Duct Kit (Hot Side) #1113: Outdoor Hood for Mini Split #1766 Line Set #1804: Heat Exchanger #1800: Specs: Capacity:2491 BTUH @ 55F Sizing: Size:35 1/16w x 18 5/8d x 6 9/16h (in) Weight:97lb Power/Rating:115V AC / 60 Hz Condensing Unit Dimensions: – 42 lbs – 13.5w x 18.9d x 9.1h Evaporator Unit Dimensions: – 55 lbs – 35.1w x 18.8d x 6.5h System Amps: – Startup: 28.2 Amps – Common dedicated 15-amp circuit is required to power the unit. – Unit Amp Rating: 8.2 Amps (high fan speed) – Total Watts: 585 (high fan speed) BTUH @ 55F / Evaporator Decibels – Low Fan Speed: 2144 / 54 dbA – High Fan Speed: 2491 / 65 dbA – 1/3 Ton Nominal Condensing Unit Decibels – Indoor: 64 – Outdoor: 62 Warranty:2 Years (Entire System) To activate your warranty, you must complete and return our Split Installation Checklist. Optional Extended Warranty sold separately. SKU:3000Scm UPC:682318846312 Evaporator Cut Sheet, Mounting Instructions, Split Systems Refrigerant Piping Handbook, Owners Manual Split Systems, Refrigerant Piping Diagram, Condensing Unit Hood, Wiring Diagram – Dual Power Valve Control, Front Ducted Evaporator Cut Sheet$3,595.00
CellarPro 6000S Split System #1764 (for cellars up to 1,500cuft)
5046 BTUH @ 55°F. CellarPro’s 6000S cooling units (3/4 Ton Nominal) are suitable for wine cellars up to 1,500 cubic feet in both commercial and residential wine cellars. The 1,500 cubic feet cellar size assumes that the cellar is constructed with insulation of R19 or better in all walls and ceiling (ie no glass or uninsulated concrete), the cooling unit is not ducted, a setpoint of 55°F inside the cellar and ambient temperatures up to 85°F outside the cellar. Performance testing shows that this unit maintains optimal cellar temperature and humidity conditions in extreme conditions up to 110°F more effectively than similar units from competing brands. 6000S units also are significantly quieter than comparable units from other brands. Visit our Learning Center for data tables, performance charts and product comparisons among different brands. DESCRIPTION: CellarPro 6000S Cooling Unit (P/N 1764). CellarPro engineered the 6000S cooling system to provide maximum cooling power and adjustable humidity control for cellars up to 1,500 cubic feet. Split refrigeration systems separate the evaporator from the condensing unit, allowing the noise and heat from the condensing unit to be located away from interior living areas. Configurable for internal or external installations, the 6000S includes a variable-speed fan on the evaporator with a low setting for quieter operation and a high setting for maximum power. This unit is designed to separate the heat and noise from the condensing unit from interior living spaces, and can be configured to operate indoors or outdoors in extreme temperature conditions ranging from -20 to 110°F. Our Evaporators are built with high-output centrifugal fans which include variable speed settings for your choice of maximum cooling power at the high fan speed, or quieter operation (53.7 decibels) at the low fan speed. Adjustable humidity control combines a high-output compressor with flexible fan cycles to maintain a recommended level of moisture inside your cellar. Extra-large coils generate maximum cooling power inside the cellar. Excess condensate is managed through a 1/2″ drain line that exits from a choice of knockouts in the evaporator. Commercial-grade Electrofin coating protects the evaporator coils from leaks and corrosion. Intuitive LED display panel with digital programmable thermostat is simple and easy to use. Energy-saver mode, quick-chill mode, and auto-defrost cycle provide convenient solutions to common cellar needs. Unit operates with minimal vibrations and less noise than comparable units from competitors. Audible and visual alarms and maintenance-needed indicator protect the cooling unit and the wine cellar. Common dedicated 20-amp circuit (valve control) or 25-amp circuit (electronic control) is required to power the unit. Adjustable mounting brackets are included as standard equipment, and multiple knockouts and access points ensure easy installation. Factory-installed Expansion Valve and Liquid Line Solenoid Valve (optional) ensure maximum operating precision and range. Removable steel case and refrigerant access valve provides access to the internal components for servicing and repair. Sight Glass and Liquid Line Filter/Drier are included for easy installation and maintenance. Oversized Receiver allows for long line sets up to 100 equivalent feet and up to 30 vertical feet. Auto-reset high-pressure switch protects the system by interrupting power to the compressor when system pressure is too high. Evaporator and Condensing Unit are factory-pressurized and shipped with dry nitrogen to ensure leak-free installation. CellarPro’s 2-Year/5-Year Warranty, the most thorough in the industry, protects the unit against manufacturing defects. An optional Extended Warranty (P/N 7528) is available for additional protection. ETL Tested and Certified to rigorous UL Standards for safety. CONFIGURATIONS: CellarPro 6000S units are designed to be installed with the evaporator inside the cellar, and the condensing unit in a remote location. Our Split refrigeration systems offer a choice of wiring: The Condensing unit can be electronically controlled by and wired to the Evaporator (single power source on the Evaporator side). This configuration allows the Condensing unit to be used in temperatures down to 20°F with the addition of our compressor heater, or down to -20°F with the addition of our fan cycling switch AND compressor heater. This configuration requires a 15-amp dedicated circuit breaker for 3000S and 4000S systems, and a 25-amp dedicated circuit breaker for 6000S and 8000S systems. The Condensing unit can be controlled by a Solenoid valve (dual power source, one each to the Evaporator and Condensing units.) This configuration allows the Condensing unit to be used in temperatures down to 20°F with the addition of our compressor heater, or 0°F with the addition of our fan cycling switch AND compressor heater. This configuration requires the evaporator to be wired to a 15-amp circuit breaker, and the condensing unit to be wired to a dedicated 15-amp circuit breaker for 3000S and 4000S systems, a dedicated 20-amp circuit breaker for 6000S systems, and a dedicated 25-amp circuit breaker for 8000S systems 6000S evaporators cannot be ducted from a remote locationand must be located inside the cellar. When the control panel is difficult to access, we offer a remote control display kit which is wired to the cooling unit and allows the digital display to be mounted inside or outside the cellar. The condensing unit requires 12 inches of unobstructed space in front of the coils, and requires approx. 600-700 CFM of ventilation when installed in a confined space. For outdoor installations, we offer an outdoor hood to protect the condensing unit from weather. All outdoor hoods include a compressor heater. The evaporator should never be exposed to temperatures below 32°F. Access to the left and right side of the evaporator unit is required for installation. All split systems must be installed and charged on site by a qualified HVAC professional. Line-set equivalent feet must be calculated in accordance with ASHRAE guidelines; refer to our Line Sizing Chart for more information. A CellarPro cooling unit must always be used in the upright position, and should never be operated on its side or upside down. We ship these units strapped to a pallet via common carrier with curbside delivery. Inside delivery is available for an additional charge. To activate your warranty, you must complete and return our Installation Checklist. OPTIONS: Cold Temperature Compressor Crankcase Heater #1727: protects the unit when installed in environments that drop down to 20°F. Fan Cycling Switch #6972: supports the unit in temperatures below 20°F and as low as -20°F when combined with our compressor heater. Hoods Outdoor Hood #2009: allows you to install the condensing unit outdoors; all outdoor hoods include a Compressor Heater #1727. Remote Control & Probe Remote Control and Display #1603: lets you place the digital panel wherever you want, whether inside or outside the cellar. Includes 10 feet of wiring. Bottle Probe #1434: this remote thermostat with a 10-foot cord overrides the thermostat on the face of the evaporator, and allows it to monitor air or liquid temperatures at various locations inside the cellar. Extension cords available in 25-foot (#1780)and 50-foot (#1781) CellarPro VS Series Enhanced Warranty #1836 CellarPro Bottle Probe #1434 Compressor Crankcase Heater #1727 Fan Cycling Switch #6972: Remote Control and Display #1603: Duct Intake Hood (Cold Side) Low RH #7408 Duct Intake Hood (Cold Side) High RH #7427 Duct Intake Kit (Cold Side) Low RH#1476 Duct Intake Kit (Cold Side) High RH#7426 Duct Hood (Hot Side) #7407 Duct Kit (Hot Side) #1113: Outdoor Hood #2009 Line Set #1807: Heat Exchanger #16733: Specs: Capacity:5046 BTUH @ 55F Sizing: Size:30 2/5w x 14 2/5d x 13 1/5h (in) Weight:121lb Power/Rating:115V AC / 60 Hz Condensing Unit Dimensions: – 54 lbs – 13.9w x 18.9d x 11.9h Evaporator Unit Dimensions: – 68 lbs – 30.4w x 14.4d x 13.2h System Amps: -Common dedicated 20-amp circuit (valve control) or 25-amp circuit (electronic control) is required to power the unit. – Startup: 53.0 Amps – Unit Amp Rating: 15.6 Amps (high fan speed) – Total Watts: 1090 (med fan speed) BTUH @ 55F / Evaporator Decibels – Low Fan Speed: 4311 / 54 dbA – Med Fan Speed: 4880 / 58 dbA – High Fan Speed: 5046 / 66 dbA – 3/4 Ton Nominal Condensing Unit Decibels – Indoor: 65 – Outdoor: 63 Warranty:2 Years (Entire System) To activate your warranty, you must complete and return our Split Installation Checklist. Optional Extended Warranty sold separately. SKU:6000S UPC:682318846299 Front Ducted Evaporator Cut Sheet, Wiring Diagram – Dual Power Valve Control, Condensing Unit Hood, Refrigerant Piping Diagram, Evaporator Cut Sheet, Mounting Instructions, Split Systems Refrigerant Piping Handbook, Owners Manual Split Systems$4,550.00
CellarPro 4000Swc Split System Water Cooled #7649 (for cellars up to 1,000cuft)
3680 BTUH @ 55°F. CellarPro’s 4000Swc cooling units (1/2 Ton Nominal) are suitable forwine cellars up to 1,000 cubic feetin bothcommercial and residentialwine cellars. The 1,000 cubic feet cellar size assumes that the cellar is constructed with insulation of R19 or better in all walls and ceiling (ie no glass or uninsulated concrete), the cooling unit is not ducted, a setpoint of 55°F inside the cellar and ambient temperatures up to 85°F outside the cellar. Performance testing shows that this unit maintainsoptimal cellar temperature and humidity conditionsin extreme conditions up to 110°F more effectively than similar units from competing brands. 4000Swc units also aresignificantly quieterthan comparable units from other brands. Visit our Learning Center for data tables, performance charts and product comparisons among different brands. DESCRIPTION: CellarPro 4000Swc Cooling Unit (P/N 7649). CellarPro engineered the 4000Swc cooling system to provide maximum cooling power and adjustable humidity control for cellars up to 1,000 cubic feet. Split refrigeration systems separate the evaporator from the condensing unit, allowing the noise and heat from the condensing unit to be located away from interior living areas. The 4000Swc includes a variable-speed fan on the evaporator with a low setting for quieter operation and a high setting for maximum power. The condensing unit requires a continuous flow of water to cool itself, and does not need ventilation like air-cooled units. This unit is designed to separate the heat and noise from the condensing unit from interior living spaces. Our Evaporators are built with high-output centrifugal fans which include variable speed settings for your choice of maximum cooling power at the high fan speed, or quieter operation (53.7 decibels) at the low fan speed. Adjustable humidity controlcombines a high-output compressor with flexible fan cycles to maintain a recommended level of moisture inside your cellar. Extra-large coils generatemaximum cooling powerinside the cellar. Excess condensate is managed through a 1/2″ drain line that exits from a choice of knockouts in the evaporator. Commercial-gradeElectrofin coatingprotects the evaporator coils from leaks and corrosion. IntuitiveLED display panelwithdigital programmable thermostatis simple and easy to use. Energy-saver mode, quick-chill mode, and auto-defrost cycle provide convenient solutions to common cellar needs. Unit operates withminimal vibrationsandless noisethan comparable units from competitors. Audible and visual alarms and maintenance-needed indicator protect the cooling unit and the wine cellar. Commondedicated 15-amp circuitis required to power the unit. Adjustable mounting brackets are included as standard equipment, and multiple knockouts and access points ensure easy installation. Factory-installed Expansion Valve and Liquid Line Solenoid Valve (optional) ensure maximum operating precision and range. Removable steel case and refrigerant access valveprovides access to the internal components for servicing and repair. Sight Glass and Liquid Line Filter/Drier are included for easy installation and maintenance. Oversized Receiver allows for long line sets up to 100 equivalent feet and up to 30 vertical feet. Auto-reset high-pressure switch protects the system by interrupting power to the compressor when system pressure is too high. Evaporator and Condensing Unit are factory-pressurized and shipped with dry nitrogen to ensure leak-free installation. CellarPro’s 2-Year/5-Year Warranty,the most thorough in the industry, protects the unit against manufacturing defects. An optional Extended Warranty (P/N 7528) is available for additional protection. CONFIGURATIONS: CellarPro 4000Swc units are designed to be installed with the evaporator inside the cellar, and the condensing unit in a remote location. Our Split refrigeration systems offer a choice of wiring: The Condensing unit can be electronically controlled by and wired to the Evaporator (single power source on the Evaporator side). This configuration requires a 15-amp dedicated circuit breaker. The Condensing unit can be controlled by a Solenoid valve (dual power source, one each to the Evaporator and Condensing units.) This configuration requires the evaporator to be wired to a 15-amp circuit breaker, and the condensing unit to be wired to a dedicated 15-amp circuit breaker. 4000Swc evaporators can belocated remotelyfrom the cellar with the addition of one of our front duct packages. Offered with or without insulated flex ducting, in a choice of configurations for low or high humidity conditions, our front duct packages allow these cooling units to beducted up to 50 equivalent feetaway from the cellar and requires 8-inch (or greater) ducting from start to finish. When calculating equivalent feet,each 90-degree turn counts for 8 feet. When the control panel is difficult to access, we offer a remote control display kit which is wired to the cooling unit and allows the digital display to be mounted inside or outside the cellar. The condensing unit requires a continuous flow of water to cool itself. The evaporator and condensing unit should never be exposed to temperatures below 32F. Access to the left and right side of the evaporator unit is required for installation. All split systems must be installed and charged on site by a qualified HVAC professional. Line-set equivalent feet must be calculated in accordance with ASHRAE guidelines; refer to ourLine Sizing Chartfor more information. A CellarPro cooling unit must always be used in theupright position, and should never be operated on its side or upside down. We ship these units strapped to a pallet via common carrier with curbside delivery. Inside delivery is available for an additional charge. To activate your warranty, you must complete and return ourInstallation Checklist. OPTIONS: Remote Control & Probe Remote Control and Display #1603: lets you place the digital panel wherever you want, whether inside or outside the cellar. Includes 10 feet of wiring. Bottle Probe #1434: this remote thermostat with a 10-foot cord overrides the thermostat on the face of the evaporator, and allows it to monitor air or liquid temperatures at various locations inside the cellar. Extension cords available in 25-foot(#1780)and 50-foot(#1781) CellarPro VS Series Enhanced Warranty #1836 CellarPro Bottle Probe #1434 Compressor Crankcase Heater #1727 Fan Cycling Switch #6972: Remote Control and Display #1603: Duct Intake Hood (Cold Side) Low RH #7408 Duct Intake Hood (Cold Side) High RH #7427 Duct Intake Kit (Cold Side) Low RH#1476 Duct Intake Kit (Cold Side) High RH#7426 Duct Hood (Hot Side) #7407 Duct Kit (Hot Side) #1113: Outdoor Hood #2011 Line Set #1804: Heat Exchanger #1800: Specs: Capacity:3680 BTUH @ 55F Sizing: Size:16 3/5w x 12 3/5d x 22 1/10h (in) Weight:86lb Power/Rating:115V AC / 60 Hz Condensing Unit Dimensions: – 45 lbs – 13.8w x 18.4d x 10.2h Evaporator Unit Dimensions (including mounting brackets): – 48 lbs – 16.6w x 12.6d x 22.1h System Amps: – Commondedicated 15-amp circuitis required to power the unit. – Startup: 32.0 Amps – Unit Amp Rating: 8.7 Amps (high fan speed) – Total Watts: 602 (med fan speed) BTUH @ 55F / Evaporator Decibels – Low Fan Speed: 3130 / 53 dbA – Med Fan Speed: 3430 / 59 dbA – High Fan Speed: 3680 / 67 dbA – 1/2 Ton Nominal Condensing Unit Decibels: 60 dbA Warranty:1 Year (Entire System)To activate your warranty, you must complete and return ourSplit Installation Checklist. Optional Extended Warrantysold separately. SKU:4000Swc UPC:682318846534 Front Ducted Evaporator Cut Sheet, Wiring Diagram – Dual Power Valve Control, Condensing Unit Hood, Refrigerant Piping Diagram Evaporator Cut Sheet, Mounting Instructions, Split Systems Refrigerant Piping Handbook, Owners Manual Split Systems$3,995.00
Reviews
There are no reviews yet.