CellarPro VS/Split Duct KIT (Cold Side) Low RH #1476

$1,035.00

SKU 1476 VS Duct KIt (Cold Side) Categories ,

Description

 

CellarPro VS/Split Duct KIT (Cold Side) Low RH (P/N 1476). Duct openings are designed to attach to two 8-inch ducts for evaporator intake and exhaust. Ducting should be 8-inch or greater from start to finish, and must not be reduced. Custom design allows access to controls and switches on the face of the cooling unit.

Requires 9 inches of additional height at the front of the cooling unit.

Kit includes: Duct hood, 50 feet (2×25) of 8-inch insulated (R-6) ducting, remote display kit and bottle probe.

The high fan speed setting is required when our unit is ducted.

Bottle Probe Operating Instructions:

  • When measuring liquid temperatures, the (HY) differential should be set at 1 degree (so that the wine liquid doesn’t fluctuate more than 1 degree.)
  • When measuring air temperatures, the (HY) differential should be set at 4 degrees (the cooling unit will burn out prematurely if the unit cycles on’off every time the air temperature changes by 1 degree.)
  • The probe or bottle/probe must be located in a location with good air movement in order to correctly register the temperature changes inside the cellar.
  • When measuring air temperature with ducted systems, the ideal location for the bottle probe is in the return air register; when measuring air temperature with through-the-wall systems, the ideal location for the bottle probe is near the return air grill; when measuring liquid temperatures in bottles, the ideal location of the bottle is near the top of the racks with good airflow.
  • In all cases, it is recommended to check the actual cellar temperature against the display temperature when the bottle probe is first setup and subsequently whenever the location moves.
  • Refer to our Owners Manual for instructions how to change the HY differential

Description;

Custom duct kit for CellarPro 3200 / 4200 VS and 3000S / 4000S Split Refrigeration Systems. With this kit, the cold air intake/exhaust can be ducted up to 100 equivalent feet (50 feet per opening).

Only recommended for use in low humidity environments. Please use our high-humidity duct kit if the system will be used in a warm, moderate or high humidity environment.

  • Attaches easily to the front of 3200/4200 VS and 3000S/4000S Split refrigeration systems
  • Designed to be used in Low Humidity environments
  • Provides access to cooling unit control panel and switches
  • Designed for easy hook-up to insulated 8″ ducting (included)
  • One or both openings may be ducted (total of 100 equivalent feet)
  • Maintains accurate temperatures inside the wine cellar
  • Includes our remote thermostat bottle probe (measures air or liquid temperatures)
  • Includes our remote control display kit

 

Configurations;

Please note: This kit is recommended for low humidity environments. Please use our high humidity duct kit if the system will be used in a warm, high humidity environment.

Be sure to refer to our ducting heat loss table and our duct correction table when sizing the cooling unit.

Options:

  • Capacity:100 Equivalent Feet
  • Size:14 3/16w x 4 11/16d x 27 1/2h (in)
  • Weight:35lb
  • Warranty:1 Year
  • UPC:691054542396

 