APEX 3500

Fully ducted cooling for smaller rooms.

APEX 3500 keeps well‑insulated cellars up to about 900 cu ft.

Remote ducting removes equipment noise from the room.

Digital controls and adaptive airflow maintain a steady set point, and a 2‑year parts and labor warranty supports long‑term reliability.

Technical Sheet-ENv4.98

1 Space & Ductwork

Wall Openings

  • Two 6″ x 12″ wall openings are installed on opposite sides of the cellar to generate effective cross-flow:
  • Supply Air: High on the wall
  • Return Air: Low on the wall

Mechanical Room Access

  • Adequate space nearby to house the cooling unit
  • Ventilation in the room is sufficient to dissipate heat

Ductwork Requirements

  • Ducts (e.g., 8″ supply and 8″ return) are planned with:
  • Maximum of 25 feet per duct (50 feet total combined)
  • Smooth, gradual bends (avoid sharp turns)
  • Ducts will be insulated to prevent condensation and minimize noise

2 Electrical & Drainage

Dedicated Electrical Circuit

  • A dedicated circuit is available for the unit:
  • Typically 115V/20A (or 120V/15A, based on your specific unit requirements)
  • No GFCI outlet is used

Drain Access

  • A drain is located within 15 inches of the unit, or a condensate pump is planned if farther away
  • Ensure proper drain line installation with a slight slope and no blockages

3 Cellar Construction & Insulation

Insulation Standards

  • Walls: Minimum R20 insulation
  • Ceiling: R20–R30 insulation
  • Floor: Minimum R20 insulation (if the cellar isn’t in a basement)

Vapor Barrier

  • A vapor barrier is installed on the warm side of the walls/ceiling

Floor & Door Considerations

  • There are no heated floors, or a 12-inch gap is maintained if present
  • The cellar door has proper seals; note that glass doors may need additional insulation

4 Ambient Conditions

Mechanical Room Temperature

  • The room housing the unit maintains an ambient temperature between 50°F and 77°F (10°C to 25°C)

Humidity Control

  • The cellar area is not prone to high humidity, reducing the risk of mold and system strain

5 Installation Preparation

Unit Handling

  • The cooling unit must be kept in an upright position, with the compressor at the bottom, for at least 24 hours before installation

3353 BTU/h

Recommended for rooms up to about 900 cu ft. Final sizing depends on insulation level, glass percentage, and ambient temperature. Let us Calculate your BTU requirements. Click Here to Contact Us.

Ideal For

  • Small private cellars, glass wine walls, compact displays, and retrofits that need quiet, concealed cooling.

Design Highlights

  • Concealed fully ducted install.
  • Digital thermostat with stable control.
  • Low vibration to protect aging.
  • Accessible panels and standard fittings for faster service.

Considerations

  • Glass and warm ambient increase heat load. If more than half the enclosure is glass or the space runs warm, add capacity margin or move to APEX 5000.

 

2‑speed fan with digital thermostat

Quiet operation for living spaces

Quick‑connect 25 ft duct kit

29.80 x 12.60 x 11.81 in

Industry Leading Warranty

2‑year parts and labor with North American support. Specs and installation include the technical sheet, cut sheet, manual, and duct and clearance diagrams.