Panthaire Apex7000

Panthaire Apex7000

$6,595.00

Panthaire Apex Series 8-inch Duct Collar Kit
Panthaire Apex Series Mounting Bracket PTH: 21041981
Panthaire Apex Series Carbon Filter PTH: 17051993
Panthaire Apex Series Condensate Pump PTH: 10151999

Description

APEX 7000

High capacity for showcase cellars.

APEX 7000 provides 6346 BTU/h for large rooms up to about 2,000 cu ft with robust insulation.

The remote, fully ducted design keeps noise outside the cellar.

Built for continuous duty with clear service access for technicians.

Technical Sheet-ENv4.98

1 Space & Ductwork

Wall Openings

  • Two 6″ x 12″ wall openings are installed on opposite sides of the cellar to generate effective cross-flow:
  • Supply Air: High on the wall
  • Return Air: Low on the wall

Mechanical Room Access

  • Adequate space nearby to house the cooling unit
  • Ventilation in the room is sufficient to dissipate heat

Ductwork Requirements

  • Ducts (e.g., 8″ supply and 8″ return) are planned with:
  • Maximum of 25 feet per duct (50 feet total combined)
  • Smooth, gradual bends (avoid sharp turns)
  • Ducts will be insulated to prevent condensation and minimize noise

2 Electrical & Drainage

Dedicated Electrical Circuit

  • A dedicated circuit is available for the unit:
  • Typically 115V/20A (or 120V/15A, based on your specific unit requirements)
  • No GFCI outlet is used

Drain Access

  • A drain is located within 15 inches of the unit, or a condensate pump is planned if farther away
  • Ensure proper drain line installation with a slight slope and no blockages

3 Cellar Construction & Insulation

Insulation Standards

  • Walls: Minimum R20 insulation
  • Ceiling: R20–R30 insulation
  • Floor: Minimum R20 insulation (if the cellar isn’t in a basement)

Vapor Barrier

  • A vapor barrier is installed on the warm side of the walls/ceiling

Floor & Door Considerations

  • There are no heated floors, or a 12-inch gap is maintained if present
  • The cellar door has proper seals; note that glass doors may need additional insulation

4 Ambient Conditions

Mechanical Room Temperature

  • The room housing the unit maintains an ambient temperature between 50°F and 77°F (10°C to 25°C)

Humidity Control

  • The cellar area is not prone to high humidity, reducing the risk of mold and system strain

5 Installation Preparation

Unit Handling

  • The cooling unit must be kept in an upright position, with the compressor at the bottom, for at least 24 hours before installation

6346 BTU/h

Recommended for rooms up to about 2,000 cu ft. Verify BTU for high‑glass or warm ambient spaces.

Ideal For

  • Large cellars

Design Highlights

  • Compact and self-contained for streamlined installation
  • Precise digital temperature regulation with whisper-quiet performance

Considerations

  • Extensive glass surfaces or lower insulation quality will reduce effective coverage

Industry Leading Warranty

2‑year parts and labor with North American support. Specs and installation include the technical sheet, cut sheet, manual, and duct and clearance diagrams.

Free Shipping for all Apex units.