Description
WineZone Cooling Systems have been discontinued. This is a direct replacement system.
Contact US for Replacement parts.
WineZone Air Handler 6200a Series
For cellars up to 2222cuft
Air Handler System
Applications:
• Used for L-shaped rooms, long narrow rooms, or where one point source will not properly circulate air throughout the room
• For cellars that will store or mature wine for long periods of time
• Located outside the cellar, the supply and return air is ducted into the room similar to a central air conditioner
• No visible mechanical equipment in cellar
• Ducted units need only supply registers and return air grilles in the cellar leaving more wall space for racking and art work
• Ducting can be placed in soffits if room construction is already complete
• The most quiet style of all refrigeration systems
• Humidification, and dehumidification air handler systems allow for total climate control in the wine cellar
• Accurate, fast acting thermostat controls the refrigeration system and all accessories
• Can be used with either an indoor or outdoor remote condensing unit, moving heat and noise away from the cellar
• Wooden and decorative metal registers available
• Must be installed and adjusted by a qualified HVAC technician
Air Handler WZAH4800a:
• ETLC listed air handler in accordance with UL1995
• Phenolic coated, aluminum fin-copper tube evaporator coil
• Factory balanced, forward curve direct drive blower, with 115V, 3 speed, PSC motor
• Cabinet with fully insulated 3/4″ fiberglass with an R value of 3.26
• 1″ disposable filters standard on all units
• Vertical units have duct connections on return air inlet and a large blower access panel in front
• Horizontal units have 3/8″ NC thread nuts in each corner of top panel for easy suspension and are designed for top or bottom blower access
Air Handler WZAH6200a and WZAH9000a:
• ETL listed and AHRI certified
• All-aluminum evaporator coil
• 230 volt, direct drive, multi-speed ECM blower motor
• Foil faced insulation with glue-less cabinet retention
• 1″ disposable filters standard on all units
• Multi-position air handler
Indoor condenser:
• UL listed Copeland® commercial condensing unit.
• Uses R134a refrigerant
• Air cooled units standard
• Receiver for use with thermostatic expansion valve
• 4″ galvanized iron base
• All units equipped with variable speed condenser fan motor speed control for quiet operation
• Crankcase heater on all models
Indoor Condenser
Outdoor Condenser:
• UL listed Copeland® commercial condensing unit.
• Uses R134a refrigerant
• Air cooled units standard
• Receiver for use with thermostatic expansion valve
• Rainproof control panel box with liquid tight conduit on control panel
• All units equipped with variable speed condenser fan motor speed control for quiet operation and low ambient control
• Crankcase heater on all models
Outdoor Condenser
Outdoor Enclosure:
• UL Listed enclosure
• Galvanized steel base
• 20 GA. Galvanized steel cabinet
• Hinged access for easier servicing
• Wind safety latch
• All season weather protection
• Front louvers at 45° angle
• Rain trough under hinge to catch moisture that might seep through hinge
• Condenser screen protected with high temperature baked-on clear lacquer coating
Peco Performance PRO Thermostat
The Performance PROT12000 Series is intended for use in residential and commercial environments. It can support the 1 stage Heat/1 stage Cool/Humidify/Dehumidify configurations for WineZone air handler systems. It features a 12 square inch blue backlit display with dynamic menus, accessed using touchscreen keys. All Performance Pro T12000 Series offer the following standard features: Auto-changeover, temporary override, optional remote temperature sensors, keypad lockout, and filter change reminder.
Advantages:
• One thermostat controls Cool, Humidify, Dehumidify, and Heat
• Blue touchscreen is large, easy to read, and user friendly.
• System configuration, while extensive, is easy and fast to perform.
• The wiring connections use common designations familiar to HVAC techs making installation of control wiring faster and simpler.
• No 115-volt power circuit is required at the thermostat reducing installation cost
• Humidify and Dehumidify are more economical since there is no need for additional controls
• Remote temperature sensor allows user to view the temperature from outside the cellar.
• Customers that purchase Dehumidification also receive the ability to heat the cellar. The Heat option with the modified condenser control panel is no longer necessary
• Provides control of Fan to customer.
• Can be used as a direct replacement for WZDS thermostats
Humidification:
Research Products Corporation is the largest manufacturer of whole house humidifiers, air cleaners, and fresh air exchangers and is a recognized leader in the heating and air conditioning industry.
• Quiet, efficient performance
• Easily installed and maintained
• Fan draws air through water panel where humidity is generated and the air handler distributes humidity throughout the cellar
• .75 gal/hr capacity, among the highest of all evaporative humidifiers
• Could humidify a 4000 sq. ft. home
• Simple yearly maintenance can be done by the HVAC tech while performing the yearly maintenance on the refrigeration system
• Fast, easy replacement of inexpensive water panel and orifice
Dehumidification for WZAH4800a:
• Duct heater suitable use in any forced air system
• Suitable for zero clearance installations in vertical or horizontal duct systems
• Easily installed in the side of the supply air duct
• Heavy gauge galvanized iron construction
• Output matched in size to refrigeration unit
Dehumidification for WZAH6200a and WZAH9000a:
• Cabinet installed electric heater kit
• Factory installed if purchased with the unit
• Rust-resistant nickel chromium for the MBVC’s heat elements, improving the unit’s longevity and performance.
• Features a plug-in wiring harness
Specifications
6200a BTUH Air Handler Specifications
Condenser:
Voltage | Ampacity Max. | Fuse Min. | Wire Size | RLA/LRA | dB |
230/208-60-1 | 8.7 | 15 | 12-2 w/Gr | 6.4/35.0 | 53 |
- Uses 5/16” x 3/4” line set up to 150 equivalent feet. Uses 3/8” x 7/8” line set from 151 to 200 equivalent feet maximum.
- 50’ of 5/16” x 3/4” line set is sent when line set is purchased with the unit.
- Unit is not precharged and must be evacuated.
- For use with R-134a refrigerant.
- Indoor condensers must be installed in a room with a minimum of 4440 cubic feet of free space.
- Dimensions:
Indoor Unit: 25″L x 20″W x 18.5″T 100 lbs.
Outdoor Unit: 25.5″L x 20″W x 20″T 126 lbs.
Multi-Position Air Handler:
Voltage | HP | Ampacity Max. | Fuse Min. | Wire Size | Filter | d |
240/208-60-1 | 3/4 | 5.8 | 15 | 14-2 w/Gr | 16 x 20 x 1 | 48 |
- Multi positon unit.
- Requires dedicated circuit from fuse panel. Ampacity, max. fuse, and wire size will change if dehumidification is used. See dehumidification below.
- 600 CFM required. 8 x 16 supply trunk, 8 x 18 return trunk recommended, 2” duct wrap min.
- 3/4” FPT drain, trap required.
- Dimensions:
Unit: 17.5″ W x 21″ D x 45″ H
Supply Opening: 11.25″ x 16.375″
Thermostat:
- Peco 12532 touchscreen 24 volt thermostat
- 18 gauge 8 conductor to condenser
Humidifier:
- Requires 115 volt receptacle
- 24 volt control from condenser
Dehumidification:
- To be installed in air handler
- 25 amp breaker required at air handler for 240 volt use, 20 amp breaker required at air handler for 208 volt use
- Heater draws 12.5 amps at 240 volts, 10.8 amps at 208 volts
Approximate Shipping Weight:
- 360-430 lbs.
Crate Size: 32″ x 72″ x 40″ T