Description
Platinum Split 4000 H.E. 220v
“Virtual Silence”
The Fully Ducted Platinum Split is WhisperKool’s newest model to the split line-up. Ducting a Split creates a virtually silent cellar environment and allows for maximum installation options. The system uses our liquid bottle probe for monitoring the actual temperature of the wine to ensure the wine is being kept at 55°F. The evaporator portion may be installed up to 25 duct feet from the cellar.
Features:
- Virtually silent operation
- Advanced electronic display
- Liquid bottle probe
- Energy saving mode
- Alarm capabilities
- Flexible installation
- 55°F temperature differential
- Condensing unit can be placed outdoors w/optional housing
- Pump down system for longer compressor life*
Improved Design:
At WhisperKOOL, we have redesigned the housing for the Platinum series split system evaporators. While the internal components have proven to be reliable and effective, we have designed new housing systems for improved installation and accessibility. The previous design was a little challenging in terms of mounting and accessing the components for installation. It required the removal of the top or side panel. When racking was installed around the unit, it was difficult to gain access for service or maintenance.
Our new design makes the units easier to install by gaining access to system from the front of the unit where we have installed removable grills. This greatly improves the ability to install the system and access it for maintenance. Please note that the dimensions have changed slightly. Review the specification section when planning your install to account for the dimensional change. At WhisperKOOL, we believe in the goal of continuous improvement in everything we do in order to enhance the customer’s experience.
Specifications
Cellar Size:
1000 cu. ft. (Properly Insulated Cellar)
dBA:
Evaporator: 54 Decibels
Condenser: 65 Decibels
Dimensions:
Evaporator: 20.5″W x 15.5″H x 14.5″D
Condenser: 12″W x 13.5″H x 18″D
Weight:
Evaporator: 57lbs
Condenser: 56lbs
AMPS (starting/running):
Evaporator: 2/1
Condenser: 15/10
Installation:
Evaporator can be installed up 25 duct feet from the cellar; Condenser is installed up to 100 line ft. away
Temp. Delta:
55°F temperature differential
Thermostat:
Digital Control Display
Warranty:
2 year parts and labor
BTUh Rating:
There are circumstances in which a cellar design may require a larger unit due to some existing design restrictions. There are several factors such as glass, stone, concrete, etc. which will seem adequate but do not offer the insulation capacity required to maintain the optimum environment. We recommend purchasing a unit with a larger capacity to compensate for the design limitations. Under sized cooling units can lead to pre-mature failure and/or prevent the system from reaching the desired set temperature. As a result they are not covered under warranty.
OPTIONS:
Cold Weather Start Kit:
Introducing the Cold Weather Start Kit by WhisperKOOL. This kit was designed exclusively for our split-systems where the condensing unit will be installed in extremely cold environments. Our split systems are designed to be adaptable to almost any install, as the condensing unit can be located in a variety of locations such as a mechanical room, basement, back yard, or even a rooftop. Our split systems were designed to operate with the condensing unit exposed to temperatures between 20° F and 110° F. However, there are some areas in the country that may drop below 20° F. Due to these conditions WhisperKOOL designed the Cold Weather Start Kit.
So, when the outside temperatures drop, the pressure in the system drops as well. This presents a challenge because our systems operate using a pump down cycle and a low pressure switch to turn the compressor on and off. However, when the temperature drops below 20° F the pressure in the system is too low to start the compressor. The use of an electronic bypass is needed to start the compressor and temperature controlled heaters installed on the receiver are needed to raise the pressure in the system to optimal levels.
The Cold Weather Start Kit will bypass the low pressure switch on startup and keep the pressure in the system high enough to operate correctly for environments as cold as -15° F.
It is important that the cooling system stays operational during cold weather conditions, as heating the house using the central HVAC system will indirectly increase the temperature of the wine cellar. This kit will ensure that the cooling system will continue to operate efficiently in cold weather environments to maintain an optimal wine storage temperature.
Warranty Overview
Self Contained System Warranty Policy
A limited 2-year product & up to an additional (6) month grace period for install /5-year compressor warranty is offered with all self-contained cooling units at the date of purchase.
Fully-Ducted Self Contained System Warranty Policy
A limited 2-year product & up to an additional (6) month grace period for install/5-year compressor warranty is offered with all self-contained cooling units at the date of purchase.
Split System Warranty Policy
A limited 2-year product warranty with up to an additional (1) year grace period for installation is offered with all split systems. While the warranty starts at the date of purchase, this warranty is not activated until a Product Warranty Checklist has been submitted and approved by WhisperKOOL.
Warranty Claims Policy
All warranty claims must be filed directly through WhisperKOOL customer service. We provide warranty repairs at our manufacturing facility in Stockton, CA, or with prior permission from WhisperKOOL to receive service by a licensed HVAC/R technician.
Limited Warranty Policy
Limited warranty applies only to wine cooling units purchased directly from WhisperKOOL or through an authorized dealer. Damage caused by others or beyond the control of WhisperKOOL shall not be considered defects in material or workmanship and is not covered by the warranty. The limited warranty does not cover any parts or labor to correct any defect caused by negligence, commercial use, accident, maintenance, installation, service/repair, or improper use.
WK-Platinum_Split_Fully_Duct-Product_Sheet WK_Platinum_Split-2nd_gen-OM WK_Platinum_Split